| SpaceTemperature | T | Temperature of the space or zone, that is required from user/designer view point. If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period. Provide this value, if no temperatur range (Min-Max) is available. | Number |
| SpaceTemperatureMax | M | Number of people required for the activity assigned to this space. | Number |
| SpaceTemperatureMin | M | Minimal temperature of the space or zone, that is required from user/designer view point. If no summer or winter space temperature requirements are given, it applies all year, otherwise for the intermediate period. | Number |
| SpaceTemperatureSummerMax | S | Maximal temperature of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling. | Number |
| SpaceTemperatureSummerMin | S | Minimal temperature of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling. | Number |
| SpaceTemperatureWinterMax | W | Maximal temperature of the space or zone for the cold (winter) period, that is required from user/designer view point and provided as requirement for heating. | Number |
| SpaceTemperatureWinterMin | W | Minimal temperature of the space or zone for the cold (winter) period, that is required from user/designer view point and provided as requirement for heating. | Number |
| SpaceHumidity | H | Humidity of the space or zone that is required from user/designer view point. If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period. Provide this property, if no humidity range (Min-Max) is available. | Number |
| SpaceHumidityMax | M | Maximal permitted humidity of the space or zone that is required from user/designer view point. If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period. | Number |
| SpaceHumidityMin | M | Minimal permitted humidity of the space or zone that is required from user/designer view point. If no summer or winter space humidity requirements are given, it applies all year, otherwise for the intermediate period. | Number |
| SpaceHumiditySummer | S | Humidity of the space or zone for the hot (summer) period, that is required from user/designer view point and provided as requirement for cooling. | Number |
| SpaceHumidityWinter | W | Humidity of the space or zone for the cold (winter) period that is required from user/designer view point and provided as requirement for heating. | Number |
| DiscontinuedHeating | D | Indication whether discontinued heating is required/desirable from user/designer view point. | Boolean |
| NaturalVentilation | N | Indication whether the space is required to have natural ventilation or mechanical ventilation. | Boolean |
| NaturalVentilationRate | R | Indication of the requirement of a particular natural air ventilation rate, given in air changes per hour. | Integer |
| MechanicalVentilationRate | R | Indication of the requirement of a particular mechanical air ventilation rate, given in air changes per hour. | Integer |
| AirConditioning | A | Indication whether this space requires air conditioning provided or not. | Boolean |
| AirConditioningCentral | C | Indication whether the space requires a central air conditioning provided or not. It should only be given, if the property AirConditioning is set to TRUE. | Boolean |
| Area Units | U | Area Units | Integer |