Name | N | Name of the Spectrum. Default will be provided | Text |
Code | C | Eurocode Version.(0=EC8_2004 1=EC8_1994) | Integer |
Country | C | Eurocode Country.(0=Other 1=CEN_Default 2=Norway 3=Singapore 4=Portugal) | Integer |
Soil | S | Soil Type(0=A 1=B 2=C 3=D 4=E 5=S1) | Integer |
Spectrum | T | Spectrum Type(0=Type_1 1=Type_2) | Integer |
Direction Vert | D | Indicates whether the ground motion direction is Vertical opposed to Horizontal. False by Default | Boolean |
Agr | A | Design ground acceleration, Agr | Number |
Soil Factor | S | The soil factor, S. This item only applies when the EURO2004Direction item is Horizontal. If the EURO2004Country item is not Other, then the input value for this item is ignored | Number |
AvgOverAg | A | The vertical ground acceleration divided by the horizontal ground acceleration, Avg/Ag. This item only applies when the EURO2004Direction item is 2 (vertical). If the EURO2004Country item is not 0, then the input value for this item is ignored. | Number |
Behaviour Factor | Q | Behaviour Factor, Q | Number |
Tb | L | The lower limit of period of the constant spectral acceleration branch, Tb. If the EURO2004Country item is not 0, then the input value for this item is ignored. | Number |
Tc | U | The upper limit of period of the constant spectral acceleration branch, Tc. If the EURO2004Country item is not 0, then the input value for this item is ignored | Number |
Td | D | The period defining the start of the constant displacement range, Td. If the EURO2004Country item is not 0, then the input value for this item is ignored. | Number |
Beta | B | The lower bound factor, Beta. If the EURO2004Country item is not 0, then the input value for this item is ignored. | Number |
Damping Ratio | X | The damping ratio for the function, 0 <= DampRatio < 1. | Number |
Damping Correction Factor | N | The damping correction factor, n, where n >= 0.7. Only Applies to CODE 1994 | Number |