Mount Type | mountType_ | Mounting type (configuration) of a module. There are three of them:
-
0 = Insulated back (pv curtain wall, pv skylights, BIPV installations with obstructed bakside airflow)
1 = Close (flush) roof mount (pv array mounted parallel and relatively close to the plane of the roof (between 5 and 15 centimenters))
2 = Open rack (ground mount array, flat/sloped roof array that is tilted, pole-mount solar panels, solar carports, solar canopies, BIPV installations with sufficient bakside airflow)
-
If not supplied, default type: "Glass/cell/glass, Close (flush) roof mount" (1) is used. | Goo |
Module Efficiency | moduleEfficiency_ | The ratio of electrical energy output from the PV module to input solar energy from the sun.
Current typical module efficiencies for crystalline silicon modules range from 14-20%
-
If not defined, default value of 15(%) will be used.
-
In percent (%). | Goo |
Temperature Coefficient | temperatureCoefficient_ | A coefficient which accounts for the percentage the solar module's DC output power decrease/increase for every degree Celsius the solar cells temperature rises above/below 25C.
-
In general it ranges from -0.44 to -0.5 for crystaline silicon modules.
-
If not supplied, -0.5 will be used as a default.
-
In %/C. | Goo |
Module Active Area Percent | moduleActiveAreaPercent_ | Percentage of the module's area excluding module framing and gaps between cells.
-
If not supplied, default value of 90(%) will be used.
-
In percent (%). | Goo |