| Name | ID | Description | Type |
|---|---|---|---|
| Ill Files Address | _illFilesAddress | List of .ill files | Goo |
| Test Points | _testPoints | List of 3d Points | Goo |
| Pts Vectors | ptsVectors_ | Script variable readDSResults | Goo |
| Occupancy Files | occupancyFiles_ | Address to a Daysim occupancy file. You can find some example in \Daysim\occ. Use Honeybee Occupancy Generator to generate a custom occupancy file. You can also use EnergyPlus Schedules directly. If the schedule is using continuous values any value larger than .2 will be considered as occupied. | Goo |
| DLAIllum Thresholds | _DLAIllumThresholds_ | Illuminance threshold for Daylight Autonomy calculation in lux. Default is set to 300 lux. | Goo |
| Lighting Control Groups | lightingControlGroups_ | Daysim lighting control groups. Daysim can model up to 10 lighting control groups together. Default is > cntrlType = 4, lightingPower = 250, lightingSetpoint = 300, ballastLossFactor = 20, standbyPower = 3, delayTime = 5 | Goo |
| SHDGroup I Sensors | SHDGroupI_Sensors_ | Senors for dhading group I. Use shadingGroupSensors component to prepare the inputs | Goo |
| SHDGroup II Sensors | SHDGroupII_Sensors_ | Senors for dhading group II. Use shadingGroupSensors component to prepare the inputs | Goo |
| Run It | _runIt | set to True to run the analysis | Goo |
| Name | ID | Description | Type |
|---|---|---|---|
| DLA | DLA | Daylight Autonomy > Percentage of the time during the active occupancy hours that the test point receives more daylight than the illuminance threshold. | Goo |
| UDLI Less 100 | UDLI_Less_100 | Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives less than 100 lux. | Goo |
| UDLI 100 2000 | UDLI_100_2000 | Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives between 100 and 2000 lux. | Goo |
| UDLI More 2000 | UDLI_More_2000 | Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives more than 2000 lux. | Goo |
| CDA | CDA | Continuous Daylight Autonomy > Similar to Daylight Autonomy except that the point receives illuminaceLevel/illuminace threshold for hours that illuminance level is less than the threshold. | Goo |
| S DA | sDA | Spatial Daylight Autonomy > sDA is the percent of analysis points across the analysis area that meet or exceed _DLAIllumThresholds value (set to 300 lux for LEED) for at least 50% of the analysis period. Honeybee doesn't consider the effect of dynamic blinds in calculating sDA. | Goo |
| Annual Profiles | annualProfiles | A .csv file generated by Daysim that can be used as lighting schedule for annual energy simulation | Goo |
| Htm Report | htmReport | Script variable readDSResults | Goo |