Read Annual Result I

Read Annual Daylight Results I [Standard Daysim Results]

Inputs

NameIDDescriptionType
Ill Files Address_illFilesAddressList of .ill filesGoo
Test Points_testPointsList of 3d PointsGoo
Pts VectorsptsVectors_Script variable readDSResultsGoo
Occupancy FilesoccupancyFiles_Address to a Daysim occupancy file. You can find some example in \Daysim\occ. Use Honeybee Occupancy Generator to generate a custom occupancy file. You can also use EnergyPlus Schedules directly. If the schedule is using continuous values any value larger than .2 will be considered as occupied.Goo
DLAIllum Thresholds_DLAIllumThresholds_Illuminance threshold for Daylight Autonomy calculation in lux. Default is set to 300 lux.Goo
Lighting Control GroupslightingControlGroups_Daysim lighting control groups. Daysim can model up to 10 lighting control groups together. Default is > cntrlType = 4, lightingPower = 250, lightingSetpoint = 300, ballastLossFactor = 20, standbyPower = 3, delayTime = 5Goo
SHDGroup I SensorsSHDGroupI_Sensors_Senors for dhading group I. Use shadingGroupSensors component to prepare the inputsGoo
SHDGroup II SensorsSHDGroupII_Sensors_Senors for dhading group II. Use shadingGroupSensors component to prepare the inputsGoo
Run It_runItset to True to run the analysisGoo

Outputs

NameIDDescriptionType
DLADLADaylight Autonomy > Percentage of the time during the active occupancy hours that the test point receives more daylight than the illuminance threshold.Goo
UDLI Less 100UDLI_Less_100Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives less than 100 lux.Goo
UDLI 100 2000UDLI_100_2000Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives between 100 and 2000 lux.Goo
UDLI More 2000UDLI_More_2000Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives more than 2000 lux.Goo
CDACDAContinuous Daylight Autonomy > Similar to Daylight Autonomy except that the point receives illuminaceLevel/illuminace threshold for hours that illuminance level is less than the threshold.Goo
S DAsDASpatial Daylight Autonomy > sDA is the percent of analysis points across the analysis area that meet or exceed _DLAIllumThresholds value (set to 300 lux for LEED) for at least 50% of the analysis period. Honeybee doesn't consider the effect of dynamic blinds in calculating sDA.Goo
Annual ProfilesannualProfilesA .csv file generated by Daysim that can be used as lighting schedule for annual energy simulationGoo
Htm ReporthtmReportScript variable readDSResultsGoo