Name | N | Name of the Spectrum. Default will be provided | Text |
Code | C | Eurocode Version. Currently only Eurocode8 2004 supported | Integer |
Soil | S | Soil Type(0=A 1=B 2=C 3=D 4=E) | Integer |
Spectrum | T | Spectrum Type(0=TYPE_1 1=TYPE_2) | Integer |
Agr | A | Peak ground acceleration, Agr | Number |
Importance Factor | I | Importance Factor, I | Number |
Damping Ratio | X | Damping Ratio, Xi | Number |
Behaviour Factor | Q | Behaviour Factor, Q | Number |
Dis Behaviour Factor | Qd | Displacement Behaviour Factor, Qd | Number |
Lower | L | Lower Bound Factor, B | Number |
Design | D | Flag to identify design spectrum | Boolean |
CQC | C | Damping options for CQC combinations(0=CODE 1=CONST 2=TABLE 3=MODE) | Integer |
Scale | S | Scale spectrum accelerations(0=CODE 1=NEWMARK_50 2=NEWMARK_84 3=ISO_19901) | Integer |
CQC Damping | D | Damping value. N/A if damping is CODE or NODE | Number |